Feature

Mrico Specimen
1 drop of finger blood

Fast Test
Glucose: 5 seconds
Uric acid: 30 seconds
Blood ketone: 5 seconds
Total cholesterol: 25 seconds

Long-Endurance
6 months or approximately 1,000 tests

Wide Range
Maximum measurement range
in same function POCT meter

Accurate
Same level of accuracy with Biochemical Analyzer

Intelligent Data
Average values of records from the last 7, 14 or 28 days

Quality Assurance
Excellent quality and advanced
technology
Multi-function Analyzer(Blood Glucose, Uric Acid, Total Cholesterol) (GUC-101) is designed to quantitatively measure glucose,uric acid or total cholesterol with fresh capillary whole blood or venous whole blood. The system is intended for use outside the human body as an aid to monitor the effectiveness of diabetes control.
To ensure accurate results:
• Read instructions before use.
• The meter should only be used with test strips which are the same trade mark as the meter
• For in vitro diagnosis only. Your meter can only be used for in vitro testing. For professional use.
• Do not change your medication or treatment plan without the permission of doctor.
• Keep out of reach of children.
• Please use the meter in the way suggested by the manufacturer, or the meter may be impaired.
Principle of measurement
The test is based on electrochemical sensor technology. The meter measures the electrical current generated by the reaction of glucose,uric acid or cholesterol with the reagent of the strip,and displays the corresponding blood glucose,uric acid and cholesterol level. The intensity of the current produced by the reaction depends on the amount of glucose ,uric acid or Cholesterol in the blood sample.
Main Features of Blood Glucose Monitoring System
• Pre-suction siphon designed test strip, easy and convenient to use
• Tiny blood sample
• Fast measuring time
• Easy to read large LCD
• Automatic 7, 14 & 28 day averages
Specfication
| Feature | Specifications |
|---|---|
| Methodology | Electrochemistry |
| Measurement Range | Glucose:20~600mg/dL, 1.1~33.3mmol/L; Uric acid:3~20mg/dL, 179~1190μmol/L; Total cholesterol:2.6~11.6mmol/L, 100~450mg/dL; |
| Specimen | Glucose: Approximate 0.5 microlitre; Uric acid: Approximate 3 microlitre; Total cholesterol: Approximate 1 microlitre; |
| Test Time | Glucose: 5 seconds Uric acid: 30 seconds Total cholesterol: 25 seconds |
| Memory | Glucose:200 records Uric acid:100 records Total cholesterol:100 records |
| Automatic Shut Off | After 1 minute of inactivity |
| Battery life | Approximately 1000 tests |
| Units of Measurement | mmol/l,μmol/l or mg/dl; Non-switchable unit |
| Meter Size | (84.7*52*18)mm(L*W*H) |
| Weight | Approximately 50 g (excluding battery) |
| Meter storage and transportationt conditions | 0 - 55°C; ≤90% RH |
| System Operating Conditions | 8℃~37℃; indoor only |
Accurate



Procedure