Multi-function Analyzer (GULP-102)

introduction

Modle

GLUP-102

Analysis Items

Total Cholesterol (TC), High Density Lipoprotein (HDL), Triglyceride (TG), Low Density Lipoprotein (LDL), Uric Acid (UA), Glucose (Glu), Creatinine (CR), Urea (UR), Hemoglobin (HB), Hematocrit (HCT)

Specimen

Whole blood(peripheral and venous human whole blood), plasma and serum

Features

Multi-function, Wide Test Range, Accurate, Quality Assurance, Rechargeable, BlueTooth Sync, Protable Printer

Power Source

4*AA Batteries

Feature

Multi-function

One meter with 9 Test functions

Wide Range

Maximum measurement range
in same function POCT meter

Accurate

Same level of accuracy with Biochemical Analyzer

Portable Printer

Contect with customized portable printer get tets result

Quality Assurance

Excellent quality and advanced
technology

Standard Battery

4*AA batteries
and support Long-Enduance

BlueTooth Sync

Sync data via bluetooth
connection mobile app

This meter can be used to measure the concentration of blood pressure (BP), total cholesterol (TC), high-density lipoprotein cholesterol (HDL), triglyceride (TG), uric acid (UA), blood glucose (GLU) concentration.

The Dry Biochemical Analysis Meter provides results. The Dry Biochemical Analysis Meter can store up to 500 results and records. The meter can be operated by charging battery.

To ensure accurate results:
  • The meter is only used with the relevant test strips produced by the company.
  • Test specimens are capillary blood, venous blood, serum or plasma.
    if the specimen contains anticoagulant, apply to whole blood and plasma containing heparin anticoagulant and whole blood containing EDTA anticoagulant ( see test strip manual for details).
  • Use the Code chip that matches the test strips correctly.
  • Use the meter only for the purpose described in the instruction manual.
  • Do not use accessories that are not provided or recommended by the manufacturer.
  • Do not use the meter if it is not working properly or is damaged.
  • Do not expose meter or its flexible wires to surfaces that are too hot to touch.
  • Do not place anything on top of the device.
  • Do not use the meter where aerosol droplets are used or where oxygen is restricted. · Do not use the meter outdoors.
  • lf the meter is not used in the manner specified by the manufacturer, the protection provided by the meter may be compromised.
  • To avoid electromagnetic interference from other devices that may affect the test results, keep the meter away from strong interference sources such as short-wave and high-frequency devices.

Specfication

  • Total Cholesterol (TC)
  • High Density Lipoprotein Cholesterol (HDL)

  • Triglycerides (TG)

  • Uric Acid (UA)

  • Urea (UR)

  • Creatinine (CR)

  • Glucose (Glu)

  • Hemoglobin (HB)

  • Low-density lipoprotein cholesterol (LDL)

  • Hematocrit(HCT)

FeatureSpecifications
MethodologyLipid/Kindey/Hemoglobin: Reflectance Photometer
Glucose: Electrochemistry
Test TimeTotal Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG) :  ≤2 min;
Uric Acid (UA),  Urea (UR) ≤2 min;
Creatinine (CR): ≤5 min;
Hemoglobin (HB), Hematocrit (HCT): ≤15 seconds;

Glucose (Glu), ≤5 seconds;
Measurement Range
  • TC: 2.59mmol/L ~ 12.93 mmol/L (100mg/dL ~500 mg/dL )
  • HDL: 0.39mmol/L ~ 2.59 mmol/L (15mg/dL ~ 100 mg/dL)
  • TG: 0.51mmol/L ~ 7.34mmol/L (45mg/dL ~ 650 mg/dL)
  • UA: 0.090mmol/L ~ 1.200mmol/L (1.51mg/dL ~ 20.17mg/dL)
  • CR: 0.044mmol/L ~ 1.320mmol/L (0.50mg/dL ~ 14.93mg/dL)
  • UR: 0.90mmol/L ~ 40.00mmol/L (5.41mg/dL ~ 60.06mg/dL)
  • Glu: 1.1mmol/L~33.3mmol/L (20mg/dL~600mg/dL)
  • HB: 0 g/dL ~ 26.0 g/dL
SpecimenFingertip blood, whole blood(capillary blood and venous wholeblood), serum or plasma
Specimen VolumeHDL+TC+TG: 35μl
HDL/TC/TG: 10μl
UR/CR/UA: 35μl
GLU: 0.5μl
HB: 5μl
Power Source4*AA batteries
Units of Measurementmg/dL, mmol/L
MemoryEach item 500 sets of records
BluetoothBluebooth to Sync Data with Phone or PC
Automatic Shut Off4 minutes after last use
Meter Size152* 123**48mm(L*W*H )
WeightAbout 365g
Meter storage and transportationt conditions(0-55)℃,<90% RH, (50-106)kPa
System Operating Conditions10-40°C;≤90% RH; Seal-Level ≤2000M
Meter Warranty Period2 Years
Meter Shelf Life4 Years

Accurate

Blood Lipid Analysis Items

Total Cholesterol (TC)

High-density Lipoprotein (HDL)

Triglycerides (TG)

renal function Analysis Items

Uric Acid (UA)

Urea (UR)

Creatinine (CR)

Hemoglobin and Glucose Analysis Items

Hemoglobin (HB)

Glucose (Glu)

Procedure

Packing

Contents

  • 1*Multi-Function Analyzer

  • 1*Carrying Bag
  • 1*User Manual Book
  • 4*AA Batteries

  • 1*Quality Guarantee Card
  • 1*QC Pass Card

related packages