Blood Glucose Test Strip (EGS-101)
Price for one tour per person
tour features
Modle | EGS-101 |
---|---|
Analysis Items | Blood Glucose (Glu) |
Specimen | Finger Blood |
Features | Wide Test Range, Accurate, Quality Assurance, Mirco Sepcimen |
Feature
Micro Specimen
1μL of finger blood
Wide Range
Maximum measurement range
in same function POCT meter
Accurate
Same level of accuracy with Biochemical Analyzer
High blood glucose level may induce diabetes related complications, such as blindness, kidney disease, nerve damage, heart , and circulatory system problems. The Diabetes Control and Complications Trial (DCCT) has confirmed that self-monitoring of blood glucose is a necessary part of the treatment plan of people with diabetes mellitus, and tight control can actually reduce the risk of diabetes related complications by about 60%. Blood Glucose Test Strip (EGS-101) is used with Blood Glucose Meter (BGM-101) or Multifunction Analysis Meter (Glucose & Uric Acid) (GUM-101) to measure glucose levels in whole blood. When the tip of the Glucose Test Strip is touched to a drop of capillary whole blood in your finger, the test strip draws the blood into the reaction chamber. Measuring time is about 5 seconds and only about 1μL blood is needed. On the monitor of the Blood Glucose Meter (BGM-101) or Multifunction Analysis Meter (Glucose & Uric Acid) (GUM-101), the test result of your blood glucose level will be displayed. The Blood Glucose Test Strip measures glucose range from 20mg/dL (1.1mmol/L) to 600 mg/dL (33.3mmol/L).
PRINCIPLE
The Blood Glucose Test Strip (EGS-101) uses electrochemical biosensor technology. A whole blood sample is drawn by capillary action into a reaction zone on the strip automatically that will achieve a stable sample volume. When the glucose in whole blood sample reacts with the reagent on the electrodes, a current can be detected by the Blood Glucose Meter (BGM-101) or Multifunction Analysis Meter (Glucose & Uric Acid)(GUM-101) when applying a fixed potential across the electrodes. The current is then converted into a reading of glucose concentration.
Specfication
Feature | Specifications |
---|---|
Methodology | Reflectance Photometer |
Test Time | hemoglobin (Hb)|Hematocrit (HCT)≤15 seconds. |
Measurement Range | hemoglobin: 4.5-25.6 g/dL (45-256g/L, 2.8-15.9mmol/L) |
Specimen | Whole blood(peripheral and venous human whole blood), plasma and serum |
Specimen Volume | 10 μL |
Units of Measurement | mg/dL, g/dL, mmol/L |
Meter storage and transportationt conditions | 0 - 55°C; ≤90% RH |
System Operating Conditions | 10 - 35°C; ≤80% RH; indoor only |