Multi-function Analyzer (GULP-101)
Price for one tour per person
tour features
Modle | GLUP-101 |
---|---|
Analysis Items | Total Cholesterol (TC), High Density Lipoprotein (HDL), Triglyceride (TG), Low Density Lipoprotein (LDL), Uric Acid (UA), Glucose (Glu), Blood Pressure (BP) |
Specimen | Whole blood(peripheral and venous human whole blood), plasma and serum |
Features | Multi-function, Wide Test Range, Accurate, Quality Assurance, Rechargeable, BlueTooth Sync, Protable Printer |
Power Source | 4*AA Batteries |
Feature
Multi-function
One meter with 6 Test functions
Wide Range
Maximum measurement range
in same function POCT meter
Accurate
Same level of accuracy with Biochemical Analyzer
Portable Printer
Contect with customized portable printer get tets result
Quality Assurance
Excellent quality and advanced
technology
Standard Battery
4*AA batteries
and support Long-Enduance
BlueTooth Sync
Sync data via bluetooth
connection mobile app
This meter can be used to measure the concentration of blood pressure (BP), total cholesterol (TC), high-density lipoprotein cholesterol (HDL), triglyceride (TG), uric acid (UA), blood glucose (GLU) concentration.
The Dry Biochemical Analysis Meter provides results. The Dry Biochemical Analysis Meter can store up to 500 results and records. The meter can be operated by charging battery.
To ensure accurate results:
-
This product is in vitro diagnostic product.
-
The meter is only used with the relevant test strips produced by the company, need to be purchased separately.
-
Test specimens are capillary blood, venous blood,serum or plasma. if the specimen contains anticoagulant, apply to whole blood and plasma containing heparin anticoagulant and whole blood containing EDTA anticoagulant(See test strip manual for details).
-
Use the Code chip that matches the test strips correctly.
-
Use the meter only for the purpose described in the instruction manual.
-
Do not use accessories that are not provided or recommended by the manufacturer.
-
Do not use the meter if it is not working properly or is damaged.
-
Do not expose meter or its flexible wires to surfaces that are too hot to touch.
-
Do not place anything on top of the device.
-
Do not use the meter where aerosol droplets are used or where oxygen is restricted.
-
Do not use the meter outdoors.
-
If the meter is not used in the manner specified by the manufacturer, the protection provided by the meter may be compromised.
-
To avoid electromagnetic interference from other devices that may affect the test results, keep the meter away from strong interference sources
such as short-wave and high-frequency devices.
Principle of measurement
The analyzer applies the principle of photochemistry and is used with test strip(LPS-101, EGS-101, EUS-101) . The whole blood sample to be tested is added into the sample area of the strip. In the process of rapid infiltration, blood cells are filtered out or dissolved. The substrate react with enzymes and chemicals in the reaction layer and lead to the color change, then the color intensity is proportional to the concentration of the substance.
Specfication
Feature | Specifications |
---|---|
Methodology | Blood lipid: Reflectance Photometer Glucose & Uric Acid: Electrochemistry Blood Pressure: Oscillometric method |
Test Time | Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG) , ≤2 min; Glucose (Glu), ≤5 seconds; Uric Acid (UA), ≤30 seconds; Blood Pressure (BP), ≤1 min; |
Measurement Range |
|
Specimen | Fingertip blood, whole blood(capillary blood and venous wholeblood), serum or plasma |
Specimen Volume | Glucose 1μL /Uric Acid 3μL /Blood Lipid 35μL |
Power Source | 4*AA batteries |
Units of Measurement | mg/dL, mmol/L |
Memory | Each item 500 sets of records |
Bluetooth | Bluebooth to Sync Data with Phone or PC |
Automatic Shut Off | 4 minutes after last use |
Meter Size | 152* 123**48mm(L*W*H ) |
Weight | About 365g |
Meter storage and transportationt conditions | (0-55)℃,<90% RH, (50-106)kPa |
System Operating Conditions | 10-40°C;≤90% RH; Seal-Level ≤2000M |
Meter Warranty Period | 2 Years |