Blood Lipid Analysis Meter (LPM-101)
Price for one tour per person
tour features
Modle | LPM-101 |
---|---|
Analysis Items | Total Cholesterol (TC), High Density Lipoprotein (HDL), Triglyceride (TG), Low Density Lipoprotein (LDL) |
Specimen | Whole blood(peripheral and venous human whole blood), plasma and serum |
Features | Multi-function, Wide Test Range, Accurate, Quality Assurance, Rechargeable, BlueTooth Sync, Protable Printer |
Power Source | Li-ion battery |
Feature
Multi-function
One meter with 3 Test functions
Wide Range
Maximum measurement range
in same function POCT meter
Accurate
Same level of accuracy with Biochemical Analyzer
Portable Printer
Contect with customized portable printer get tets result
Quality Assurance
Excellent quality and advanced
technology
Rechargeable
Built-in 1200mAh Li-ion battery
and support Long-Enduance
BlueTooth Sync
Sync data via bluetooth
connection mobile app
The Blood Lipid Analysis System is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG), and the calculated ratio of TC/HDL and Low Density Lipoprotein Cholesterol (LDL) in peripheral and venous human whole blood, plasma and serum. The Blood Lipid Analysis System provides results. The Blood Lipid meter can store up to 500 results and records. The meter can be operated by charging battery.
To ensure accurate results:
- Read instructions carefully and complete any necessary training before use.
- Use the code chip that is included in each box of test strips.
- Only use the Blood Lipid Test strips with the Blood Lipid Meter.
- For in vitro diagnostic use only. Your Blood Lipid Analysis system is only to be used outside the body for testing purposes.
- Keep out of reach of children.
Principle of measurement
The analyzer applies the principle of photochemistry and is used with blood lipid test strip (LPS-101) .The whole blood sample to be tested is added into the sample area of the strip. In the process of rapid infiltration, blood cells are filtered out or dissolved. The substrate reacts with enzymes and chemicals in the reaction layer and lead to the color change, then the color intensity is proportional to the concentration of the substance.
The analyzer tests the color intensity of the reaction end point at the wavelength of 620nm, the substance concentration is calculated by the reflection coefficient. With the following formula the concentration of low density lipoprotein cholesterol in (LDL) is calculated, the ratio of TC and HDL can also be calculated.
LDL=TC-HDL-TG/5 (mg/dL) or LDL=TC-HDL-TG/2.2 (mmol/L)
Specfication
Feature | Specifications |
---|---|
Methodology | Reflectance Photometer |
Test Time | Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG) ≤2 min; |
Measurement Range |
|
Specimen | Whole blood(peripheral and venous human whole blood), plasma and serum |
Specimen Volume | 35 μL |
Power Source | charging battery; Note: during charging, the meter is not operatable |
Units of Measurement | mg/dL, mmol/L |
Memory | 500 records |
Automatic Shut Off | 5 minutes after last use |
Meter Size | 135mm×66mm×19mm |
Weight | 90g |
Meter storage and transportationt conditions | 0 - 55°C; ≤90% RH |
System Operating Conditions | 10 - 35°C; ≤80% RH; indoor only |