Lipid Testing System (LP-101)
introduction
Modle | LP-101 |
---|---|
Analysis Items | Total Cholesterol (TC), High Density Lipoprotein (HDL), Triglyceride (TG), Low Density Lipoprotein (LDL) |
Specimen | Whole blood(peripheral and venous human whole blood), plasma and serum |
Features | Multi-function, Wide Test Range, Accurate, Quality Assurance, Protable Printer |
Power Source | 3 x AAA battery |
Feature

Multi-function
One meter with 3 Test functions

Wide Range
Maximum measurement range
in same function POCT meter

Accurate
Same level of accuracy with Biochemical Analyzer

Quality Assurance
Excellent quality and advanced
technology

battery replacement
Use 3 AAA batteries
and support Long-Enduance

Portable Printer
Contect with customized portable printer get tets result
The Lipid Testing System is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG), and the calculated ratio of TC/HDL and Low Density Lipoprotein Cholesterol (LDL) in capillary and venous human whole blood, plasma, and serum. The easy to operate system consists of a portable meter that analyzes the intensity and color of light reflected from the reagent area of a test device, ensuring quick and accurate results.There are two models available: LP-101 and LP-102.
The Lipid Testing System provides results in less than 2 minutes. The meter can store up to 200 results and records can be transferred to a computer for further analysis using the USB port. For Model LP-102, The records can also be transferred to a mobile terminal by bluetooth. For The meter can be operated by 3 AAA (1.5V) batteries.
To ensure accurate results:
-
Read instructions carefully and complete any necessary training before use
-
Use the code chip that is included in each box of test devices.
-
Only use the Lipid Test Devices with the Lipid Meter.
-
For in vitro diagnostic use only.
-
Sample type: Fresh capillary blood, heparinized or EDTA venous whole blood, serum and heparinized plasma can be tested.
-
Please test within the expired date of all components.
Principle of measurement
The analyzer applies the principle of photochemistry and is used with blood lipid test strips (LPS-101 TCS-101 TGS-101 HLS-101) .The whole blood sample to be tested is added into the sample area of the strip. In the process of rapid infiltration, blood cells are filtered out or dissolved. The substrate reacts with enzymes and chemicals in the reaction layer and lead to the color change, then the color intensity is proportional to the concentration of the substance.
The analyzer tests the color intensity of the reaction end point at the wavelength of 620nm, the substance concentration is calculated by the reflection coefficient. When the test strip is LPS-101,with the following formula the concentration of low density lipoprotein cholesterol in (LDL) is calculated, the ratio of TC and HDL can also be calculated.
LDL=TC-HDL-TG/5 (mg/dL)
or
LDL=TC-HDL-TG/2.2 (mmol/L)
Specfication
Feature | Specifications |
---|---|
Methodology | Reflectance Photometer |
Test Time | Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG) ≤2 min; |
Measurement Range |
|
Specimen | Whole blood(peripheral and venous human whole blood), plasma and serum |
Specimen Volume | 10 μL for individual test; 25 μL for 3-in-1 test |
Units of Measurement | mg/dL, mmol/L |
Power Source | Batteries: 3 AAA (LR03) Mini USB, 5V dc, 50 mA, Use only AC/DC adapter or PC certified and recommended. |
Battery Life | 85 hours or 1,000 tests |
Memory | 200 records |
Automatic Shut Off | 5 minutes after last use |
Display Size | 50 mm × 50 mm (1.97” ×1.97”) |
Meter Size | 142 mm × 70 mm × 27 mm |
Weight | 130 g (without batteries) |
Data Transfer | USB, bluetooth (only for LP-102) |
Meter storage and transportationt conditions | 0 - 50ºC (32 -122ºF); ≤ 90% RH; height≤ sea level 2000m |
System Operating Conditions | 15 - 40ºC (59 -104ºF); ≤ 90% RH; height≤ sea level 2000m |
Accurate
Blood Lipid Analysis Items
Total Cholesterol (TC)

High-density Lipoprotein (HDL)

Triglycerides (TG)

Procedure
Packing